Administration login

From Swivel Knowledgebase Wiki

Jump to: navigation, search


Image:logo.gif


Contents

Overview

Common issues related to logging into the PINsafe administration console


Prerequisites

PINsafe 3.x


Symptoms

Cannot login to the Administration Console


Solution

Default settings

By default the following information is required:

Username: admin

Password:

OTC: extracted from a PIN of 1234


Check Network connectivity

Ensure that the PINsafe instance can be reached through the network, usually on port 8080.


Is the Administration Login Page accessible

If the PINsafe Administration Console login screen is not visible, or a pinsafe/error page is displayed see Tomcat problems

If a PINsafe Administration Console login screen is visible, check the following:


Problems with Administration Console Logon

  • One Time Code is entered in password field instead of the OTC field, by default there is no password.
  • PIN number is entered instead of the One Time Code, the PIN should never be entered
  • Wrong default login details, The default username is admin, the default PIN is 1234, the password is not set by default except in error in PINsafe build 3.5.2989 Auto Reset manually disabling
  • Use port 8080, port 8443 is not enabled for Administration login
  • User is locked or disabled, login as another user with admin or helpdesk privileges
  • Is ChangePIN on first login set? (It will allow the first login, but not subsequent logins)
  • IE 6 may stop the Turing image from appearing (PINsafe 3.5), or the login page from appearing altogether (PINsafe 3.7). Check the security level and security settings.
  • If a red cross appears where the Single Channel Turing graphical image should be, and the image is unavailable for authentication, then this could be due to the wrong java version, particularly where animated images are used with older versions of java, or where file permissions and ownerships are incorrect see Permissions and Ownership.
  • Ensure that the Tomcat Webapps folder does not have multiple instances of PINsafe that have been copied from the installed pinsafe folder. Multiple instances of PINsafe can be used, but need to be created from a .war file rather than copying the existing install to a new folder.
  • Disk space, use df -k at the command line to see if there is sufficient disk space. If the partition is full where PINsafe is installed, it may mean that an attempted write to the config.xml file has failed and is 0 length and needs to be restored from a backup or recreated. See also Appliance Disk full
Personal tools