Getting Started Basic CMI configuration
From Swivel Knowledgebase Wiki
Contents |
Overview
This outlines the basic steps in setting up a PINsafe appliance using the CMI (Command Management Interface). Each PINsafe appliance must be configured.
Note: The CMI must be used for setting system information. Changes made elsewhere may invalidate its support.
Prerequisites
PINsafe appliance running CMI
The following Networking information is required for each PINsafe appliance.
- IP Address
- Netmask
- Gateway
- VIP (Where used)
Optional information that can be configured at this stage is:
- Routing Information
- DNS Servers
- NTP Server
- Heartbeat boot status (used for the VIP)
- Monitor Heartbeat status (used for the VIP)
Connecting to the PINsafe server
Connect to each PINsafe Appliance in one of the following ways:
- VM Console
- KVM
- SSH on default Ethernet port (see the PuTTY How To Guide for more information)
For further information see Console Access How to guide
Default Ethernet Ports on Appliances
The PINsafe appliances supports the use of up to 3 Network Interfaces (VM's need to create the additional interface). The following default IP addresses are used:
Standalone/DR ETH0 192.168.0.35
Primary of A/A ETH0 192.168.0.36 ETH1 172.16.0.1
Standby of A/A ETH0 192.168.0.37 ETH1 172.16.0.1
A/A VIP 192.168.0.38
Login
Login to each PINsafe appliance with:
username: admin
password: lockbox (assuming the password has not been changed)
Set Network Interfaces
For each PINsafe appliance nn the CMI Main Menu select Advanced Menu
select Networking
select IPs & Routing
select Change Appliance IPs
select Appliance IPs on eth0 (The standalone appliance has one Ethernet port Eth0, A/A appliances two Eth0 and Eth1)
When asked to stop the Tomcat service answer Yes
Enter the following Information (options will vary depending on appliance type):
- New appliance IP
- New appliance Netmask
- New Default gateway
- New Standby appliance IP (or Primary for Standby, not applicable on Standalone)
- New Virtual Appliance IP (Where being used, if it is not required, leave it at the default value)
When asked Are you sure enter Yes if all information is correct
When asked Restart network interfaces now?, only answer yes if on the local console or there is connectivity on the new network address
For appliances using A/A MySQL, the replication Ethernet interface may be set, see Changing the Ethernet Replication Port
VIP Activation
On the Primary Master and Standby Master, from the CMI Main Menu select Advanced Options, then Default Running Services. Select the following options so that they will display ON and start automatically after a reboot:
Heartbeat
Mon
To activate them immediately select these from the Main Menu, and start each in turn.
For more information on using the VIP see VIP on PINsafe Appliances.
Start Tomcat
On each PINsafe appliance, from the CMI Main Menu select Tomcat
Then Start
Tomcat should then indicate it is running.
Verify Connectivity
Ensure that the PINsafe appliances can be connected across the network. They should respond to a ping.
MySQL Status
For PINsafe appliances using the MySQL DB (i.e. the Active Primary Appliance, Active Standby Appliance, DR Appliance, and not the Standalone Appliance), check that MySQL is running and that the status is as expected.
On the PINsafe CMI, from the Main Menu select MySQL
then status of Master/Slave
PINsafe Appliance version 2.0.14 will show status as synchronised or not synchronised
PINsafe Appliance version 2.0.13 and earlier shows the following
Ensure the Primary Appliance Master Position is the same number as the Slave on the Standby Appliance
Ensure the Standby Appliance Master Position is the same number as the Slave on the Primary Appliance
Ensure all Slave IO Running are Yes
Ensure all Slave SQL Running are Yes
This should all be working fully before proceeding. To ensure that they are in synchronisation see MySQL Appliance Database Synchronisation
CMI Password Change
It is recommended to change the CMI Password on each appliance, see Password change for CMI How to Guide
Configuring PINsafe
When the required networking information has been set then Configure each PINsafe appliance through the PINsafe Administration consoles.
Note: It is recommended that where required, PINsafe is updated to the latest version before configuration, rather than upgrade a configured installation, see Upgrade PINsafe.