Difference between revisions of "Timezone"

From Swivel Knowledgebase
Jump to: navigation, search
(Troubleshooting)
(Timezone Overview)
 
(3 intermediate revisions by one other user not shown)
Line 6: Line 6:
 
= Timezone Overview =
 
= Timezone Overview =
  
Each Swivel database will use the Timezone of the Swivel server that writes data into it. All instances of Swivel should be set to the same Timezone. The Timezone should be set before configuring the Swivel application, and a restart made of the database.
+
Each Swivel database will use the Timezone of the Swivel server that writes data into it. '''All instances of Swivel that use the same database should be set to the same Timezone''': credentials set using one timezone are not valid in another. The Timezone should be set before configuring the Swivel application, and a restart made of the database.
  
 
The Swivel appliances are by default set to use GMT with daylight savings (BST).
 
The Swivel appliances are by default set to use GMT with daylight savings (BST).
  
 
To change the Timezone after adding users obliges to reset pins for those users.
 
To change the Timezone after adding users obliges to reset pins for those users.
 
  
 
= Prerequisites =
 
= Prerequisites =
Line 38: Line 37:
  
 
= Known Issues =
 
= Known Issues =
 
+
After a migration the error message: "The user does not have a PIN set" might mean a Timezone configuration issue between the backup version and the newer one.
 
 
  
 
= Troubleshooting =
 
= Troubleshooting =
 +
For migration issues check the Timezone configurations.

Latest revision as of 09:33, 12 June 2018


Timezone Overview

Each Swivel database will use the Timezone of the Swivel server that writes data into it. All instances of Swivel that use the same database should be set to the same Timezone: credentials set using one timezone are not valid in another. The Timezone should be set before configuring the Swivel application, and a restart made of the database.

The Swivel appliances are by default set to use GMT with daylight savings (BST).

To change the Timezone after adding users obliges to reset pins for those users.

Prerequisites

Swivel 3.x


Swivel appliance Timezone change

Changing the Timezone on a Swivel appliance is done through the Webmin.

On each of the Swivel appliances set the timezone to be the same timezone, from the Webmin select Hardware, then System Time and then the tab for Change timezone. Select the required timezone then click save. It is not recommended to have Swivel instances on different timezones.

Restart the database after setting the timzone, for internal restart Tomcat, for MySQL restart MySQL on each Swivel instance after the change is made.


Swivel Appliance Hardware System Time.jpg


Swivel Appliance Hardware System Time Change Timezone.jpg


Testing

Known Issues

After a migration the error message: "The user does not have a PIN set" might mean a Timezone configuration issue between the backup version and the newer one.

Troubleshooting

For migration issues check the Timezone configurations.