Difference between revisions of "VIP Status"
m (1 revision imported) |
|
(No difference)
|
Latest revision as of 12:52, 11 May 2017
Contents
Overview
This document details how to check the VIP Status on a Swivel appliance. For information on VIP configuration see VIP on PINsafe Appliances, for further information on Swivel HA see High Availability with PINsafe.
Prerequisites
Swivel appliance
Heartbeat Status
PINsafe VIP Status Check through the CMI
On each Swivel Appliance in the cluster (Primary Master, Standby Master, but not DR)
1. Login to the PINsafe Command Management Interface (See CMI).
2. Select Heartbeat
3. Select Status
4. Check VIP is on the expected server (usually always on the primary
If the Primary appliance is shutdown, the VIP should fail across to the Standby appliance.
Swivel VIP status check through the command line
From the command line run the following:
service heartbeat status
- If it's not started you'll get something like:
[admin@standby ~]# service heartbeat status heartbeat is stopped. No process
- If it is started you'll get something like:
[admin@standby ~]# service heartbeat status heartbeat OK [pid 6855 et al] is running on standby.swivel.local [standby.swivel.local]...
Testing
Shutdown Primary Master, observe VIP on Standby, start Primary Master, observe VIP on Primary and Standby
Known Issues
Running multiple Swivel HA clusters without a cross over cable, on the same network may cause issues as they use multicast on port 694 UDP by default.
Troubleshooting
Heartbeat will not start see Heartbeat issues
Check the /var/log/messages on each appliance for error messages related to heartbeat, see Troubleshooting Files FAQ